Pool Heating Energy Calculator
Estimate ideal thermal energy and heating time before environmental losses.
Your result
EVERYDAYEnter your values and select calculate.
On this page How it works & practical examples
How to use the Pool Heating Energy Calculator
The power input is electrical consumption. COP converts it into delivered heat; a heat pump can have a COP above one under suitable conditions. Use a justified average COP for the scenario.
The calculation
Worked example
20 m³ warmed by 5°C needs about 116.3 kWh of thermal energy. A 5 kW electrical heater at COP 1 takes 23.26 ideal hours without losses.
Assumptions and limits
Assumes water density 1,000 kg/m³ and constant heat capacity. Heat loss, evaporation, circulation and temperature-dependent efficiency are omitted, so real heating can take longer.
Common questions
Is heater thermal output the same as electrical input?
Only at COP 1 in this model. If using thermal output directly, set COP to one and label the assumption accordingly.
Does this set a safe pool temperature?
No. Start and target temperatures are inputs, not recommendations.